Replace the Battery
c.
Check the NTP policy for the /SP/clock.
-> show /SP/clock usentpserver
Properties:
usentpserver = enabled
d.
If enabled, set the property to disabled.
-> set /SP/clock usentpserver=disabled
2.
Replace the battery.
Replacing the battery is a cold-service procedure. The server must be completely powered off
and power cables disconnected before performing this procedure.
a.
Prepare the server for service.
b.
Remove memory risers CM0/MR0, CM0/MR2 and CM0/MR3.
c.
Remove the old battery
Gently push the battery toward the memory risers to release it from the retention clip.
118 SPARC T7-2 Server Service Manual • July 2019