III–1
3. Malfunctions and Displays
(1) Malfunctions without any display
The circuit breaker trips when power is turned on
Short circuit or ground fault of the crankcase heater, current leakage in electrical parts
Circuit breaker trips when operated
Current leakage or short circuit in fan or coolant pump, current leakage or short circuit in electrical parts
Poor cooling
1) Problem in refrigeration circuit
Clog in refrigeration circuit, faulty 4-way valve, faulty electric valve in indoor/outdoor unit, compression
failure, or shortage of refrigerant.
Shutoff valve not completely open
2) Small fan capacity
Clogged air lter, foreign matter in air inlet, outlet
3) Other
Insuf cient refrigerant tubing insulation
Poor heating
1) Problem in refrigeration circuit
Clog in refrigeration circuit, faulty 4-way valve, faulty electric valve in indoor/outdoor unit, compression
failure, or shortage of refrigerant.
Shutoff valve not completely open
2) Other
Insuf cient refrigerant tubing insulation
Heating on standby does not clear
Warm air is striking the room temperature sensor, temperature around room temperature sensor is high,
faulty indoor control board
Auto- ap does not move well
1) The aps swing, but wind direction cannot be set
Auto- ap limit switch is faulty or has a bad connection
2) Does not move (swing, air direction setting)
Auto- ap is faulty, indoor control board is failed, remote controller is faulty
Loud operation noise or vibration noise
1) Noise or vibration when fan operates
Fan is unbalanced, worn motor axis bearing, loose fan securing screw
2) Loud operation noise or vibration noise when compressor operates
Something is coming into contact with the refrigerant tubing or compressor
Water leakage
1) Drain water leakage
Clogged drain tube, mistake in draintube construction, insuf cient draintube insulation
2) Condensation on refrigerant tubing
Insuf cient tubing insulation
3) Condensation at duct outlet
Insuf cient wind capacity, gap between duct connections
Does not stop
Fused magnetic contactors, faulty indoor/outdoor control board, faulty remote controller
No display on the remote controller
Remote controller wiring disconnected
Remote controller wiring shorted