EasyManua.ls Logo

Panasonic 2WAY Multi - L04 Duplicate System (Outdoor Unit) Address Setting

Panasonic 2WAY Multi
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IV–69
L04 Duplicate System (Outdoor Unit) Address Setting
Error detection method
An error is determined when identical system (outdoor unit) addresses exist within the same link wiring.
When the system (outdoor unit) address settings were forgotten during link wiring.
When the system (outdoor unit) address settings were accidentally duplicated during link wiring.
When link wiring was performed with a water heat exchanger unit connected.
Troubleshooting
1
System
address
1-1
Check to ensure that unique system addresses has been set for each outdoor unit connected
to the same link wiring (indoor/outdoor operation wiring). Correct any duplicate addresses that
are found and perform the auto-addressing process.
2
Link wiring
forbidden
2-1
Link wiring is not possible when the water heat exchanger unit is connected. Disconnect the
link wiring.