Panasonic 2WAY Multi - Page 12

Panasonic 2WAY Multi
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
III–3
: Flashing : Lit : Off
Detection Item
Warning
Display
Wireless Remote Control
Lamp Display
Device
Checked
Sensor errors
Indoor unit sensor
errors
Indoor heat exchanger inlet temperature
sensor error (E1)
F01
Operating
Timer
Wait...
Alternate ashing
Indoor unit
Indoor heat exchanger outlet temperature
sensor error (E3)
F03
Indoor unit intake temperature sensor
error
F10
Indoor unit discharge temperature sensor
error
F11
Operating
Timer
Wait...
Alternate ashing
Lit
Outdoor unit
Outdoor unit sensor
errors
Compressor outlet temperature sensor
error
F04
Outdoor heat exchanger inlet temperature
sensor error
F06
Outside air temperature sensor error F08
Compressor inlet temperature sensor
error
F12
Coolant temperature sensor error F13
Compressor inlet/outlet pressure sensor
error
F16
Hot water outlet temperature sensor error
(for only models that discharge hot water)
F17
Exhaust gas temperature sensor error F18
Clutch coil temperature sensor error F20
Flashing
Operating
Timer
Wait...
Temperature sensor error for oil level
measurement (for only W MULTI)
H08
Compressor oil depletion error (for only W MULTI) H07
Indoor nonvolatile memory (EEPROM) error (*1) F29
Operating
Timer
Wait...
Simult. ashing
Indoor unit
Real time clock (RTC) function F30
Operating
Timer
Wait...
Simult. ashing
Lit
Outdoor unit
Outdoor nonvolatile memory (EEPROM) error F31
Invalid or missing setting
Inconsistencies in indoor/outdoor unit models (non-GHP
equipment connected)
L02
Operating
Timer
Wait...
Simult. ashing
Indoor unit
Multiple main units set for group control L03
Duplicate indoor unit
priority setting
(priority indoor unit) L05
Outdoor unit
(excluding priority indoor unit) L06
Group control wire present for individual-control indoor unit L07
Indoor unitIndoor unit address not set L08
Indoor unit capacity not set L09
Duplicate system (outdoor unit) address setting L04
Operating
Timer
Wait...
Simult. ashing
Lit
Outdoor unit
Outdoor unit capacity not set L10
Indoor unit model setting failure L13
Indoor unit pairing failure L15
Gas type setting failure L21
When the water heat exchanger unit is connected in the table above, please replace indoor unit with water
heat exchanger unit for the alarm.
Note: Some items are not indicated, depending in model.
GHPtroubleshooting.indbIII‒3GHPtroubleshooting.indbIII‒3 2012/11/2611:20:032012/11/2611:20:03