High Speed Pulse Dial—Break Width
Specifies the maximum length of the break signal in a high speed pulse dial.
High Speed Pulse Dial—
Pulse % Break on this screen determines the value that can be specified here.
Default
32 ms
Value Range
4 ´ n (n=4–18) ms
Maintenance Console Location
3.10 [1-1] Slot—Card Property - LCO type
Programming Manual References
3.11 [1-1] Slot—Port Property - LCO Port
Feature Manual References
None
High Speed Pulse Dial—Make Width
Specifies
the minimum length of the make signal in a high speed pulse dial.
High Speed Pulse Dial—
Pulse
% Break on this screen determines the value that can be specified here.
Default
20 ms
Value Range
4 ´ n (n=3–15) ms
Maintenance Console Location
3.10 [1-1] Slot—Card Property - LCO type
Programming Manual References
3.11 [1-1] Slot—Port Property - LCO Port
Feature Manual References
None
Pulse Type
Selects the type of pulse dial transmission appropriate to your area.
Default
Normal
108 PC Programming Manual Document Version 2010-11
3.10 [1-1] Slot—Card Property - LCO type