4.18 [2-10] Extension CID Settings
Various settings for extension Caller ID can be programmed.
Extension Caller ID Resource-1, 2 (KX-TDA50 only)
Specifies a group of 4 SLT ports that can transfer Caller ID information to connected SLTs.
When
the port to which an extension is connected has this feature activated, there will be a short delay before
the extension rings for incoming calls.
Default
Disable
Value Range
Disable: No port
Slot 01:DHLC4: Initially installed 4 Super Hybrid ports
Slot nn:SLC4: Ports 1 to 4 of the SLC4 card (nn=slot number)
Slot nn:SLC8 1-4: Ports 1 to 4 of the SLC8 card (nn=slot number)
Slot nn:SLC8 5-8: Ports 5 to 8 of the SLC8 card (nn=slot number)
Maintenance Console Location
4.18 [2-10] Extension CID Settings
Programming Manual References
6.1 [4-1-1] Wired Extension—Extension Settings—Option 8—
Extension Caller ID
Feature Manual References
3.1.1 Caller ID
Extension Caller ID Modulation Type
Specifies the modulation frequency to be used when sending Caller ID information to an SLT.
Default
Bell202(Bellcore)
Value Range
V.23(ETSI), Bell202(Bellcore)
Maintenance Console Location
4.18 [2-10] Extension CID Settings
Programming Manual References
None