11.3 [9-3] Network Operator (VoIP)
This
screen allows network operators to be programmed. A network operator is an extension at a remote PBX
that will monitor other PBX extensions using Network Direct Station Selection (NDSS). The settings on this
screen should be programmed at the PBX that is to be monitored (
Network Data Transmission for
Centralized Operator Feature
—Network PBX ID 2–8). Up to 8 network operators can be programmed.
Network Operator Extension No.
Specifies the number of an extension at the monitor PBX (the PBX whose Network Data Transmission
for
Centralized Operator Feature—Network PBX ID is set to 1 in 11.2 [9-2] Network Data Transmission).
Any extension at the monitor PBX can be specified here.
Default
Not stored.
Value Range
Max. 16 digits (consisting of 0–9, *, and #)
Maintenance Console Location
11.3 [9-3] Network Operator (VoIP)
Programming Manual References
11.2 [9-2] Network Data Transmission—
Network Data Transmission for Centralized Operator Feature—
Network PBX ID
Feature Manual References
13.1.15 Private Network Features—NDSS (Network Direct Station Selection)
IP-GW Card Slot No. to notify BLF data to Network Operator
Specifies the slot number (with the KX-TDA600
, shelf and slot number) of the card used to send extension
status data. This setting is only required when using VoIP to transmit data.
Default
Undefined
Value Range
For KX-TDA50:
Undefined, 5–7
For KX-TDA100/KX-TDA200:
Undefined, 1–11
For KX-TDA600:
Undefined, 1-1–4-11