3.23 [1-1] Slot—Card Property - IP Extension—
Common Settings
IP
network data transmission settings can be programmed. To activate any changes made to settings on this
screen, it is necessary to set all installed IP-EXT cards to OUS, then back to INS.
Gateway Address
Specifies the default gateway address of the IP network.
Default
0.0.0.0
Value Range
0.0.0.0–223.255.255.255
Maintenance Console Location
3.23 [1-1] Slot—Card Property - IP Extension—Common Settings
Programming Manual References
3.22 [1-1] Slot—Card Property - IP Extension—
Gateway Address [Common Settings]
Feature Manual References
9.1.15 IP-PT (IP Proprietary Telephone)
Voice (RTP) UDP Port No. (Server)
Specifies the UDP port used by the IP-EXT card to transmit and receive RTP (Realtime Transfer Protocol)
data. This must be changed if another network application is using the same port.
For voice communications, an
IP-EXT16 card uses 64 and an IP-EXT4 card uses 16 contiguous UDP ports,
starting from the port number specified here.
Default
8000
Value Range
1024–65472
Maintenance Console Location
3.23 [1-1] Slot—Card Property - IP Extension—Common Settings
Programming Manual References
None
Document Version 2010-11 PC Programming Manual 195