13.3 [11-3] Power Failure Transfer (KX-TDA100/
KX-TDA200/KX-TDA600
only)
When the power supply to the PBX fails, power failure transfer (PFT) switches the current connections to
Auxiliary Connections, so that certain SLTs and CO lines can be connected. Auxiliary Connections allow CO
line calls to be made during a power failure. Up to 6 pairs of CO line cards and extension cards that are
physically connected by RJ11 cable can be specified. The conversations through the lines specified here will
be maintained even when the power returns.
For the KX-TDA600, select the shelf for which to set connections from the Shelf list. Note that PFT connections
can only be made within the same shelf.
Trunk Card Slot No.
Specifies the position of the CO line card to be used.
Default
Current slot number
Value Range
None, 1–11
Maintenance Console Location
13.3 [11-3] Power Failure Transfer (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
13.1.9 Power Failure Transfer
Extension Card Slot No.
Specifies the position of the extension card to be used.
Default
Current slot number
Value Range
None, 1–11
Maintenance Console Location
13.3 [11-3] Power Failure Transfer (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Document Version 2010-11 PC Programming Manual 783