Default
Not stored.
Value Range
Max. 20 characters
Maintenance Console Location
6.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
None
Feature Manual References
None
Outgoing Preferred Line
Selects the line to be seized after going off
-hook to make a call.
Default
For KX-TDA50:
ICM
For KX-TDA100/KX-TDA200/KX-TDA600:
ICM/PDN
Value Range
For KX-TDA50:
No Line: No line is seized.
Idle: An idle CO line is seized automatically from the programmed trunk groups.
ICM: An extension line is seized.
F-1–F-36: A CO line programmed for a flexible button (F-1–F-36) is seized. A flexible button customized as a
Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected.
For KX-TDA100/KX-TDA200/KX-TDA600:
No Line: No line is seized.
Idle: An idle CO line is seized automatically from the programmed trunk groups.
ICM/PDN: An extension line is seized, or, for a PDN extension, an idle PDN button is selected.
F-1–F-36: A CO line programmed for a flexible button (F-1–F-36) is seized. A flexible button customized as a
Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected.
Maintenance Console Location
6.1 [4-1-1] Wired Extension—Extension Settings
Programming Manual References
6.5 [4-1-4] Wired Extension—Flexible Button
Document Version 2010-11 PC Programming Manual 501
6.1 [4-1-1] Wired Extension—Extension Settings