Parker Hannifin S.p.A. Divisione S.B.C. user’s manual TWIN-N and SPD-N
151
OBJECT DESCRIPTION
INDEX 605Bh
Name Shutdown option code
Object Code VAR
Data Type INTEGER16
Category Optional
ENTRY DESCRIPTION
Access rw
PDO Mapping No
Value Range INTEGER16
Default Value 0
DATA DESCRIPTION
Value Description
-32768 ... –1 manufacturer specific
0 Disable drive function
1 Slow down with slow down ramp; disable of the drive function
2 ... 32767 reserved
10.3.2.4 Object 605Ch: Disable operation option code
The parameter
disable operation option code determines what action should be taken if there
is a transition OPERATION ENABLE
SWITCHED ON. OBJECT DESCRIPTION
INDEX 605Ch
Name Disable operation option code
Object Code VAR
Data Type INTEGER16
Category Optional
ENTRY DESCRIPTION
Access rw
PDO Mapping No
Value Range INTEGER16
Default Value 1
DATA DESCRIPTION
Value Description
-32768 ... -1 manufacturer specific
0 Disable drive function
1 Slow down with slow down ramp and then disabling of the drive function
2 ... 32767 reserved