4.3.16.3 Event Status
This page allows the user to inspect the current Link OAM Link Event configurations, and change them as well. as screen in
Figure 4-3-16-3 appears.
Figure 4-3-16-3: Link OAM Statistic Page Screenshot
The page includes the following fields:
General Settings
Object Description
Port
The switch port number.
Sequence Number
This two-octet field indicates the total number of events occurred at the remote end.
Frame Error Event
Timestamp
This two-octet field indicates the time reference when the event was generated, in
terms of 100 ms intervals.
Frame error event
window
This two-octet field indicates the duration of the period in terms of 100 ms intervals. 1)
The default value is one second. 2) The lower bound is one second. 3) The upper
bound is one minute.
Frame error event
threshold
This four-octet field indicates the number of detected errored frames in the period is
required to be equal to or greater than in order for the event to be generated. 1) The
default value is one frame error. 2) The lower bound is zero frame errors. 3) The
upper bound is unspecified.
Frame errors
This four-octet field indicates the number of detected errored frames in the period.