2-17
VIBXPERT 11.2010
Getting started - Basic settings
Note
Note
Advanced VIBCODE handling
When measurement tasks performed at a VIBCODE measurement
location are not only taken by the VIBCODE sensor but by another
vibration sensor, VIBXPERT recognizes these and assigns them to
another measurement channel.
-E
NABLED: Measurement tasks with the VIBCODE sensor are per-
formed on the VIBCODE sensor channel. The other measurements
are taken on the other channel.
-D
ISABLED: The measurement tasks are measured on one channel,
each with the sensor that has been set up.
Disable sensor detection
This shortens the duration of the entire measurement.
·E
NABLED: Sensor detection is deactivated. The sensor symbol is
crossed out. If several measurements are taken of a single
measurement location, VIBXPERT only performs the sensor detec-
tion and cable test before the first measurement.
·D
ISABLED: Sensor detection is active. Prior to every measurement,
VIBXPERT checks whether the correct sensor is connected and if
the cable is OK. A sensor icon appears at the upper edge of the
screen next to the battery icon.
When measurements are taken with the VIBCODE sensor, sensor
detection is always active!
Disable hardware settling
This shortens the duration of the entire measurement.
-E
NABLED: Amplifiers to not settled before measurement starts.
-D
ISABLED: Amplifier stages settle before measurement starts.
Measurement error may occur if the amplifier stages do not settle first!
When sensor detection is active (see above), the amplifiers always
settle. The settings in this field are ignored.
Triax sensor
Use the triaxial sensor in the route. The ICP sensors that were
assigned to the triax measurement location in OMNITREND are only
replaced by the triax sensor if this option is activated. Also, the
measurement tasks are grouped into the three spatial directions (X, Y
and Z) to be measured according to the following scheme:
Measure X and Y signals simultaneously on channels A and B, then
change to channel B to measure the Z signal.
Standard vibration sensor
Here you define the sensor to be used for all vibration measurements
on a route. The settings in OMNITREND are ignored. The 'Triax
sensor' option is disabled.
Sensor detection
enabled disabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PRÜFTECHNIK VIB 5.300 Series and is the answer not in the manual?

PRÜFTECHNIK VIB 5.300 Series Specifications

General IconGeneral
BrandPRÜFTECHNIK
ModelVIB 5.300 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals