882 Video Test Instrument User Guide (Rev A.35) 139
Note 2: The 1B-01 test should be run for both
settings of this parameter only if the Source Out
Only Repeater is set to yes. If Source Out Only
Repeater is set to no, this parameter is ignored
in the HDCP CTS 1.1 test.
Note 3: The 1B-01 test should be run for both
settings of this parameter for the HDCP CTS 1.2
test.
12. Press the Tools key get back to the Reports menu.
13. Select HDCP to access the HDCP compliance test menu.
The following is displayed on the 882’s LCD.
14. Select !CompRpt to initiate the HDCP compliance test. Initiate each test individually.
The message “HDCP Compliance Test” is shown and then all the tests are shown in
sequence.
Alternatively, you can run the tests through the command line as shown below:
CPTX:CPTR 21 // Selects specific test (e.g. 3A_01) see table below
CPTX:CPTU // Initiates the execution of the test
You can query the complete list of tests to choose from:
CPTX:GCTN? // Queries the list of tests supported
You can query the currently selected test to run with:
CPTX:CPTU? // Queries the selected test to run (see table)
Refer to “To view the HDCP compliance report:” on page 605 for procedures on how to
view the generated report.
15. Monitor the 882EA LCD for a set of prompts during the 3A-01, 3A-05 and 3B-01 tests.
a. When prompted with the screen shown below, examine the video on the display
connected to 882EA output 1. Press the appropriate button adjacent to the
indication (Yes! or No!) to continue.
Note: The prompt asks you if the video appearing on the connected display looks
good. “Looks good” means that there is a picture and an absence of excessive snow.
!CompRpt EditPCP
Does the video look
good?
!Yes No!