RFL 9660 RFL Electronics Inc.
August 18, 1998 7-2 (973) 334-3100
Table 7-1. Short-form responses and long-form equivalents
Short-Form Response
(“B” Command)
(1)
Verbose ASCII (“F” Command)
(2)
#P Number of ports [number of ports]
BF Brief response format
BP Invalid password
C# Checking port number [port number]
CC Command cancelled
DP Parameters are [parameters]
DS Current port deselect code is [deselect code]
ER ERROR
ES EEPROM checksum
F# Failed at port number [port number]
FA *****FAILED*****
FD Diagnostics
FL The fiber optic loop is operating
FM Fiber optic master absent
H* “LOCAL>“ or “MODEM>“ prompt
LD DCD lost while in menu
LP Please enter new label, up to [number of characters]
LR Long response format
MP Connected to port # [number of selected port]
NF EEPROM failure
NV EEPROM size is [number of bytes]
OL Old label was [old label]
P# Logged on as number [user number]
P# Port number [number of selected port]
P> Cannot select port > than {highest port number; 8, 16, 24, or 32]
PA Passed
PE Port number must be 1 - [highest port number; 8, 16, 24, or 32]
PR Local disconnect button pressed
PW Please enter password
R# ROM IS [ ]
RD Remote disconnect active
RM Reset in progress ...