EasyManua.ls Logo

RFL Electronics RFL 9660 - Page 162

Default Icon
312 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RFL 9660 RFL Electronics Inc.
April 24, 2007 13-9 (973) 334-3100
Command: &Fn Load Factory Settings
Values:
n = 0
Default:
None
Description
&F0 Load factory settings as active configuration.
Note: See also the Z command.
Command: &Gn V.22bis Guard Tone Control
Values:
n = 0, 1, or 2
Default:
0
Description
&G0 Disable guard tone.
&G1 Set guard tone to 550 Hz.
&G2 Set guard tone to 1800 Hz.
Note: The &G command is not used in North America.
Command: &Kn Flow Control Selection
Values:
n = 0, 3, or 4
Defaults:
3
Description
&K0 Disable flow control.
&K3 Enable CTS/RTS hardware flow control.
&K4 Enable XON/XOFF software flow control.
Command: &Ln Leased Line Operation
Values:
n = 0, 1, or 2
Defaults:
0
Description
&L0 The modem is set for standard dial-up operation.
&L1 The modem is set for leased line operation in originate mode.
&L2 The modem is set for leased line operation in answer mode.
Note: For &L1 and &L2, there is a 30-second window between power up and the
starting of the leased line handshake. During this time, you can turn off the
command, if desired.
Command: &Pn Pulse Dial Make-to-Break Ratio Selection
Values:
n = 0, 1, or 2
Default:
0
Description
&P0 60/40 make-to-break ratio
&P1 67/33 make-to-break ratio
&P2 20 pulses per second
Note: The &P2 command is available only if the country code is set to Japan.

Table of Contents