PCU and Quenching Lamp 
SM 4-21 D115/D116 
Replacement 
and 
Adjustment 
4.6  PCU AND QUENCHING LAMP 
When handling the photo conductor unit (PCU), use caution: 
  Do not touch the OPC drum with your bare hands. When the OPC drum is unclean, clean it 
with dry cloth, or clean it with wet cotton and wipe it with dry cloth. 
  Do not use alcohol or any other chemicals to clean the OPC drum. These substances 
damage the OPC-drum surface. 
  Keep PCUs in a cool, dry place. 
  Do not expose the OPC to any corrosive gas such as ammonia. 
  Do not shake a used PCU. Remaining toner and developer may spill out. 
  Dispose of used PCUs in accordance with local regulations.