Bit Switches 
D115/D116 5-22  SM Appendix 
 
7 
Action when a fax SC has 
occurred 
0: Automatic reset 
1: Fax unit stops 
0: When the fax unit detects a fax SC code other 
than SC1201 and SC1207, the fax unit 
automatically resets itself. 
1: When the fax unit detects any fax SC code, the 
fax unit stops. 
Cross Reference 
Fax SC codes - See “Troubleshooting” 
 
5.2.2 I-FAX SWITCHES  
 
I-fax Switch 00 - Not used (do not change the settings) [SP No. 1-102-001] 
 
I-fax Switch 01 [SP No. 1-102-002] 
No 
FUNCTION  COMMENTS 
Original Line Resolution of TX 
Attachment File 
These settings set the maximum resolution of the 
original that the destination can receive. 
0 200x100 Standard 
0: Not selected 
1: Selected 
If more than one of these three bits is set to “1”, 
the higher resolution has priority. For example, if 
both Bit 0 and Bit 2 are set to “1” then the 
resolution is set for "Bit 2 200 x 400. 
1 200x200 Detail 
2 200x400 Fine 
3  300 x 300 Reserve 
4  400 x 400 Super Fine 
5  600 x 600 Reserve 
6 Reserve