Adjusting Copy Image Area 
SM 4-65 D115/D116 
Replacement 
and 
Adjustment 
SP  Specification 
SP4-009-001 (Main Scan Mag)  ± 1.0% 
SP4-008-001 (Sub Scan Mag)  ± 1.0% 
 
Scan Auto Adjustment 
This procedure adjusts the standard white density level. Adjust the standard white density after 
any of the following maintenance work: 
  Replacing the standard white plate 
  Replacing the BICU 
  Replacing the lens block 
  Executing the memory clear (SP5-801-002 [basic model], SP5-998-001 [other models]). 
1.  Place 10 sheets of new A4 paper on the exposure glass. 
2.  Close the platen cover. 
3.  Activate the SP mode. 
4.  Select Copy SP4-428. 
5.  Specify "1" and press the OK key. The copier automatically adjusts the standard white 
density.