SC Tables
D115/D116 6-14 SM
No.
Definition
Symptom Possible Cause/Countermeasure
636 SD Card Error
-001 B
Expanded authentication module error
There is no expanded
authentication module in the
machine.
The SD card or the file of the
expanded authentication module is
broken.
There is no DESS module in the
machine.
1. Install the correct SD card or the
file of the expanded
authentication module.
2. Install the DESS module.
-002 B
Version error
The version of the expanded
authentication module is not
correct.
1. Install the correct file of the
expanded authentication
module.
650 Communication error of the remote service modem (Cumin-M)
-001 C
Authentication error
The authentication for the
Embedded RCG-M fails at a dial up
connection.
1. Check and set the correct user
name (SP5816-156) and
password (SP5816-157).
-004 C
Incorrect modem setting
Dial up fails due to the incorrect
modem setting.
1. Check and set the correct AT
command (SP5819-160).
-005 C
Communication line error
The supplied voltage is not
sufficient due to the defective
communication line or defective
connection.
1. Consult with the user's local
telephone company.