SC Tables
D115/D116 6-20 SM
No.
Definition
Symptom Possible Cause/Countermeasure
822
Self-diagnostic error: HDD (Hard Disk Drive)
[XXXX]: Detailed error code
When the main switch is turned on or starting the self-diagnostic, the HDD
stays busy for the specified time or more.
[3003] C Timeout error Loose connection
Defective HDD
Defective controller
1. Check that the HDD is correctly
connected to the controller.
2. Replace the HDD.
Replace the controller.
[3004] C Command error
823 Self-diagnostic Error: NIB
[6101] C
MAC address check sum error
The result of the MAC address
check sum does not match the
check sum stored in ROM.
Defective controller
1. Replace the controller.
[6104] C
PHY IC error
The PHY IC on the controller
cannot be correctly recognized.
Same as SC823-[6101]
[6105] C
PHY IC loop-back error
An error occurred during the
loop-back test for the PHY IC on
the controller.
Same as SC823-[6101]