System Service Mode
D115/D116 3-12 SM Appendix
4015*
White Plate Scan
4015 1
Start position
[–3.0 to +6.0 / 0.0 / 0.1 mm/step]
Adjusts the scanning start position on the white plate. The base value is 17.8
mm from the scanner home position. This SP specifies the offset from this
base value.
4015 2
Scanning Length
[–3.0 to +6.0 / 0.0 / 0.1 mm/step]
Adjusts the distance of the white plate scan. The scan begins from the start
position (SP4-015-001) and ends at the specified distance. The base value is
2.0 mm. This SP decides the offset from this base value. Specify 0 (zero) or a
larger value.
4428
Scan Auto Adj
4428 1
Conducts the automatic scanner adjustment. Use this SP after replacing the
white plate (
"Scanning" in the section "Replacement and Adjustment").
4606
SBU Offset-Target
4607 1 EVEN
[0 to 63 / 10 / 1 /step]
Adjusts the target black level for each signal.
These are used for offset adjustment in the SBU.
4607 2 ODD
4607 3 RED
4607 4 GREEN
4607 5 BLUE