System Service Mode
SM Appendix 3-17 D115/D116
Appendix:
SP Mode
Tables
4903*
ADS Level
[0 to 255 / 252 / 1/step]
4903 1 Adjusts the ADS level.
4904*
ADS Lower Limit
[0 to 255 / 80 / 1/step]
4904 1 Adjusts the ADS lower limit.
4905*
ADS Area Select
[0 = All / 1 = One]
4905 1
Checks the whole area (0 = All) or the specific areas (1 = One) to adjust the
ADS level. The specific areas are as follows:
ARDF: ±37.5 mm from the center
Platen Cover: 15 to 90 mm from the left edge
4921*
Image Adj Selec
001
Copy [0 to 10 / 0 / 1]
Selects which mode the settings from SP4-922 to SP4-932 are used for.
0 = None, 1 = Text 1, 2 =Text 2, 3= Photo 1, 4 = Photo 2, 5 = Photo 3, 6 =
Special 1, 7 = Special 2, 8 = Special 3, 9 = Special 4,
10 = Special 5
002
Fax
[0 to 5 / 0 / 1]
Selects which mode the settings from SP4-922 to SP4-932 are used for.
0 = None, 1 = Text 1, 2 = Text 2, 3 = Photo 1, 4 = Photo 2,
5 = Special 1
003
Scanner (Mono)
[0 to 4 / 0 / 1]
Selects which mode the settings from SP4-922 to SP4-932 are used for.
0 = None, 1 = Text 1, 2 = Text 2, 3= Photo 1, 4 = Photo 2
004
Scanner (Color)
[0 to 2 / 0 / 1]
Selects which mode the setting of SP4-935 is used for.
0 = None, 1 = Color Text, 2 = Color Photo