System Service Mode
D115/D116 3-120 SM Appendix
Num. Component
026 Polygon M
027 Polygon M/LD
028 LD
029 DF-Feed M
030 DF-Transport M
031 DF-Feed CL
034 DF-Gate SOL (Junction Gate Solenoid)
038 Fusing SOL
When checking Fan Motor High (005) or Fan Motor Low (006) note the following:
These motors may not respond when the fusing temperature is high.
Selecting "ON" checks that one of these motors normally operates. Selecting "OFF" turns
off the motor that you have started by selecting "ON." However, this does not guarantee
that the motor normally stops during normal operation.