EasyManua.ls Logo

Ricoh Aficio MP201SPF - Page 410

Ricoh Aficio MP201SPF
542 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fax Error Codes
D115/D116 4-6 SM Appendix
0-33
The data reception (not
ECM) is not completed
within 10 minutes.
Check the line connection.
The other terminal may have a defective
modem/NCU/FCU.
0-52
Polarity changed during
communication
Check the line connection.
Retry communication.
0-55
FCU does not detect the
SG3.
FCU firmware or board defective.
SG3 firmware or board defective.
0-56
The stored message data
exceeds the capacity of the
mailbox in the SG3.
SG3 firmware or board defective.
0-70
The communication mode
specified in CM/JM was
not available
(V.8 calling and called
terminal)
The other terminal did not have a compatible
communication mode (e.g., the other terminal
was a V.34 data modem and not a fax
modem.)
A polling tx file was not ready at the other
terminal when polling rx was initiated from the
calling terminal.
0-74
The calling terminal fell
back to T.30 mode,
because it could not detect
ANSam after sending CI.
The calling terminal could not detect ANSam
due to noise, etc.
ANSam was too short to detect.
Check the line connection and condition.
Try making a call to another V.8/V.34 fax.
0-75
The called terminal fell
back to T.30 mode,
because it could not detect
a CM in response to
ANSam (ANSam timeout).
The terminal could not detect ANSam.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.

Table of Contents