Fax Error Codes
D115/D116 4-8 SM Appendix
0-84
The line was disconnected
due to abnormal signaling
in V.34 phase 4 – control
channel start-up.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
0-85
The line was disconnected
due to abnormal signaling
in V.34 control channel
restart.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
0-86
The line was disconnected
because the other terminal
requested a data rate
using MPh that was not
available in the currently
selected symbol rate.
The other terminal was incompatible.
Ask the other party to contact the
manufacturer.
0-87
The control channel started
after an unsuccessful
primary channel.
The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
This does not result in an error
communication.
0-88
The line was disconnected
because PPR was
transmitted/received 9
(default) times within the
same ECM frame.
Try using a lower data rate at the start.
Try adjusting the cable equalizer setting.
2-11
Only one V.21 connection
flag was received
Replace the FCU.
2-12 Modem clock irregularity Replace the FCU.
2-13 Modem initialization error
Turn off the machine, then turn it back on.
Update the modem ROM.