Bit Switches
SM Appendix 5-51 D115/D116
Appendix:
Fax Service
Program
6
Parameter selection for dial
tone detection
0: Normal parameter
1: Specific parameter
0: This uses the fixed table in the ROM for dial tone
detection.
1: This uses the specific parameter adjusted with
SRAM (69ECBEH - 69ECDEH). Select this if the dial
tone cannot be detected when the "Normal
parameter: 0" is selected.
7
Not used
Do not change the settings.
G3 Switch 08 - Not used (do not change the settings)
G3 Switch 09 - Not used (do not change the settings)
G3 Switch 0A [SP No. 1-105-011]
No FUNCTION COMMENTS
0-1
Maximum allowable carrier
drop during image data
reception
Bit 1: 0, Bit 0: 0 = 200
Bit 1: 0, Bit 0: 1 = 400
Bit 1: 1, Bit 0: 0 = 800
Bit 1: 1, Bit 0: 1 = Reserved
These bits set the acceptable modem carrier
drop time.
Try using a longer setting if error code 0-22 is
frequent.
2
Select cancellation of
high-speed RX if carrier signal
lost while receiving
0: Off
1: On
This switch setting determines if high-speed
receiving ends if the carrier signal is lost when
receiving during non-ECM mode
3
Not used
Do not change the settings