NCU Parameters
SM Appendix 5-71 D115/D116
Appendix:
Fax Service
Program
Address Function Unit Remarks
stored in address
68054F is used.
Do not set a number
more than 7 in the UK.
68055E
Progress tone detection level, and
cadence detection enable flags
Bit 7: 0, Bit 6: 0, Bit 5: 0 = -25.0 dBm
Bit 7: 0, Bit 6: 0, Bit 5: 1 = -35.0 dBm
Bit 7: 0, Bit 6: 1, Bit 5: 0 = -30.0 dBm
Bit 7: 1, Bit 6: 0, Bit 5: 0 = -40.0 dBm
Bit 7: 1, Bit 6: 1, Bit 5: 0 = -49.0 dBm
Bits 2, 0 - See Note 2.
68055F
To
680564
Not used
-
Do not change the
settings.
680565 Long distance call prefix (HIGH) BCD For a code of 0:
680565 – FF
680566 - FF
680566 Long distance call prefix (LOW) BCD
680567
to
680571
Not used
-
Do not change the
settings.
680572
Acceptable ringing signal
frequency: range 1, upper limit
1000/ N
(Hz).
SP2-103-003
(parameter 02).
680573
Acceptable ringing signal
frequency: range 1, lower limit
SP2-103-004
(parameter 03).
680574
Acceptable ringing signal
frequency: range 2, upper limit
SP2-103-005
(parameter 04).
680575
Acceptable ringing signal
frequency: range 2, lower limit
SP2-103-006
(parameter 05).
680576
Number of rings until a call is
detected
1
SP2-103-007
(parameter 06).
The setting must not be
zero.