SP Mode Service Tables
J012/J013/J014 5-48 SM
1010 REG:MAN:OHP:F Adjust Main Scan Registration (Bypass: OHP: FA)
Use this SP code to adjust writing in the main scan direction for transparencies
(OHP) loaded in the bypass tray. Do this setting when registration does not
match the image start position on the user image adjustment menu.
[-128 to +127/FA/1/0.1 mm]
1011 REG:FD2:NORM:F
Adjust Sub Scan Registration (Normal Paper: 2nd
Registration: FA)
Use this SP code to adjust writing in the sub scan registration for normal paper.
Do this setting when it is necessary to fine adjust the line feed position.
[-128 to +127/FA/1/0.1 mm]
1012 REG:FD2:GLOS:F
Adjust Sub Scan Registration (Glossy Paper: 2nd
Registration: FA)
For Future Use. Use this SP code to adjust writing in the sub scan registration
for glossy paper. Do this setting when it is necessary to fine adjust the line feed
position.
[-128 to +127/FA/1/0.1 mm]
1013 REG:FD2:OHP:F
Adjust Sub Scan Registration (OHP: 2nd Registration:
FA)
For Future Use. Use this SP code to adjust writing in the sub scan direction for
transparencies (OHP). Do this setting when it is necessary to fine adjust the
line feed position.
[-128 to +127/FA/1/0.1 mm]