368
Resolution
---
9bit ,0.015V
Accuracy at 25 °C
---
± (Max.0.02)V
Accuracy at 55 °C
---
± (Max.0.04)V
Isolation between analog
channel and power supply
---
None
Cable length
---
10 m max. shielded and twisted
Output parameters:
Output No.
2 (Q1-Q2)
Output type
Relay output
Continuous current
Resistive load 10A/Inductive load 2A
Max. breaking voltage
AC 250 V /DC 110 V
Max. Allowable Power Force
1250VA /300W
Electrical durability
Expectancy
10
5
Operations at Rated Resistive Load
Mechanical life
10
7
Operations at No Load condition
Response time
Operate Time : 15 mSec. Max.
Release Time : 10 mSec. Max.
Built-in protections
Against short-circuits: None
Against overvoltages and overloads: None
Switch frequency:
Mechanism
10Hz
Resistor/light load
2Hz
Sensitive load
0.5Hz
Other parameters:
Function blocks
64 blocks
RTC accuracy :
MAX ±2S/day
RTC Backup at 25 °C
20 days
Program and settings
Backup
10 Years
Data Power-off retentivity
No
Weight
Approx.180g
Short-circuit protection
External fuse required
Cycle time
typ. 0.6ms 8.0ms
Connection cables
2 x 1.5 mm² or 1 x 2.5 mm²
Ambient temperature
-20 to + 55 ºC
Storage temperature
–40 ºC to + 70 ºC
Certification
CE
Mounting
On 35 mm standard mounting rail, 4 MW, or wall-mounting
Dimensions
W x H x D (48*90*64 mm)
Programming cable
PC cable, (RS232 or USB)
Third party device(HMI)
<=> xLogic
Yes (work as modbus slave)
Extensions
No

Table of Contents