ROBOT S6
7. MAINTENANCE INFORMATION
7.1. MAINTENANCE INSTRUCTIONS
‒ A good maintenance will allow for a longer working life and constant compliance with the
safety requirements.
‒ Before performing any operation, the authorised operator must make sure that he/she
understood the "Instructions for use".
‒ Pay attention to the SAFETY WARNINGS, do not use the machine for UNSPECIFIED
PURPOSES and assess the possible RESIDUAL RISKS.
‒ Carry out the interventions with all the safety devices enabled and wear the DPI provided.
‒ Mark the intervention area and prevent access to the devices that, if activated, may cause
unexpected hazards and jeopardize the safety level.
‒ DO NOT carry out any intervention that is not described in the manual but contact an
Assistance Service authorised by the manufacturer.
‒ DO NOT damp in the environment materials, pollutant liquids and the residues created
durin
the interventions but dis
ose them accordin
to the standards in force.
7.2. MAINTENANCE PERIOD TABLE
he table below specifies the routine maintenance intervals to be followed to ensure top performances,
longer working life and constant compliance with the safety requirements.
Frequency Component Type of
intervention
Procedure Reference
Every 40 hours or
1000 cycles
∗
Machine operating
areas
Cleaning Use a cloth
or
compressed
air
-
Every 200 hours
or 5000 cycles
∗
Rubber coated
rollers
Cleaning Use a cloth
dampened
with alcohol
-
Every 200 hours
or 5000 cycles
∗
Reel carriage Lubricate - See “Lubrication
point diagram”
Every 200 hours
or 5000 cycles
∗
Reel carriage Check chain
slack
- See “Reel
carriage lifting
chain adjustment”
Every 200 hours
or 5000 cycles
∗
Reduction gears
and gearmotors
Check
lubricant
level ¹
Top up, if
necessary
See “Lubrication
point diagram”
Every 2000 hours
or 10000 cycles
∗
Reel carriage Check chain
wear
Replace
chain, if
worn out
Contact the
Technical Service
authorized by the
Manufacturer
Every 2000 hours
or 10000 cycles
∗
Inductive sensors Check
efficiency
Adjust the
distance
between the
stops (2 mm)
-
Every 2000 hours
or 10000 cycles
∗
Safety devices Check
efficiency
Have any
faulty
device
replaced
Contact the
Technical Service
authorized by the
Manufacturer