ROBOT S6
E80 - ALL. BATTERY
CHARGER.
Charge battery
alarm.
Battery charge
failure.
Check the battery
charger and refer
to the wiring
diagram.
E81 - H.M.I. COMUNIC.
FAULT.
Communication
alarm at the
touch screen.
The cable is
unplugged or the
touch screen is
faulty.
Check the
operation of the
touch screen
panel and refer
to the relevant
electric diagram.
E82 - PRESTRETCH
COMUNIC.
FAULT.
Faulty serial
communication
with pre-stretch
card alarm.
The cable is
unplugged or the
board is faulty.
Check the
operation of the
board and refer
to the relevant
electric diagram.
E84 - CHECKSUM
PARAMETRI
CONFIGURAZIONE
ERRATO
Setup parameters
incorrect alarm.
Machine setup
parameter list is
corrupted.
To restore
default setup
parameters,
insert into the
USB port on the
back of the HMI
the key supplied
with the machine
and press the
button (A)
.
You can also set
the parameters
manually by
pressing the
button (B)
∗∗
.
E85 - CREASING
COMUNIC. FAULT.
Creasing device
communication
alarm.
The cable is
unplugged or the
board is faulty.
Check the
operation of the
board and refer
to the relevant
electric diagram.
E90 - BATTERY LOW. Battery low
alarm.
The battery has
run down to the
safety level; the
machine will
stop.
Transport the
machine to the
nearest charge
point using the
manual
forward/back
buttons on the
steering arm.
see "control
description".