The motor reports an overvoltage
fault.
Power being supplied to the
QSHT inverter is above +830V
DC. See Overvoltage Fault on
page 246.
The fault clears once the power
bus drops below +820V DC.
Verify the voltage output from the
power supply.
Verify the voltage at the motor.
Reduce power cable resistance
between motors that share a com-
mon HVDC power supply.
Reduce maximum speed and/or
maximum acceleration to reduce
the amount of regenerated power
that flows back into the system.
Increase the spacing between
vehicles on motors that share a
common HVDC power supply.
Connect more motors to a com-
mon HVDC power supply to
increase the number of blocks
available to absorb regenerated
power.
Table 8-3: Power-Related Troubleshooting (Continued)
Symptom Problem Description Corrective Action

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation MagneMotion QuickStick HT and is the answer not in the manual?

Rockwell Automation MagneMotion QuickStick HT Specifications

General IconGeneral
BrandRockwell Automation
ModelMagneMotion QuickStick HT
CategoryAccessories
LanguageEnglish

Related product manuals