Design Guidelines
Transport System Design
QuickStick HT User Manual 99
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
MICS File Example
Figure 3-28 is an example of a QSHT system with Ethernet motors. Figure 3-29 is the MICS
file for that system.
Figure 3-28: System Layout for MICS File Example
Figure 3-29: MICS File Example
<?xml version=“1.0” encoding=“US-ASCII”?>
<!-- MICS Motor Data file for a MagneMotion Transport System -->
<!-- $Rev: 002 $ $LastChangedDate: 2020-06-04 16:06:34 (Thu, 4 Jun 2020) $ -->
<MICS_motor_data>
<!-- PATH 1 -->
<Motor> <!-- P1M1 -->
<Mac_addr>C0:6C:6D:E0:00:20</Mac_addr> <!-- Motor MAC address -->
<IP_addr>10.14.1.1</IP_addr> <!-- Motor IP address -->
<Track_location>P1M1</Track_location> <!-- Track NC Path, Motor # -->
</Motor>
<Motor> <!-- P1M2 -->
<Mac_addr>C0:6C:6D:E0:00:21</Mac_addr> <!-- Motor MAC address -->
<IP_addr>10.14.1.2</IP_addr> <!-- Motor IP address -->
<Track_location>P1M2</Track_location> <!-- Track NC Path, Motor # -->
</Motor>
<Motor> <!-- P1M3 -->
<Mac_addr>C0:6C:6D:E0:00:28</Mac_addr> <!-- Motor MAC address -->
<IP_addr>10.14.1.3</IP_addr> <!-- Motor IP address -->
<Track_location>P1M3</Track_location> <!-- Track NC Path, Motor # -->
</Motor>