EasyManua.ls Logo

Rockwell Automation MagneMotion QuickStick HT

Rockwell Automation MagneMotion QuickStick HT
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Design Guidelines
Transport System Design
96 MagneMotion
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
IP_addr
Purpose
Identifies the static IPv4 address of the drive for the motor.
Syntax
<IP_addr>IPaddress</IP_addr>
Attributes
None
Parent Tag
<Motor>
Contents
IPaddress – A 32-bit IP address in IPv4 dotted-decimal format, “ddd.ddd.ddd.ddd”, where
ddd is a decimal number of up to three digits in the range 0 to and 255. See Ethernet Motor
Communication Recommendations on page 79.
Validation
Node controller requirements for startup and initialization:
Must not contain any child tags.
Must contain a string in IPv4 dotted-decimal notation.
Must not be values of 0.0.0.0, 127.0.0.1, 255.255.255.255, or the node controller sub-
net broadcast address.
Must not contain a value that is equal to another <IP_addr> tag.
Example
<IP_addr>192.168.110.76</IP_addr>

Table of Contents

Related product manuals