Protocol Analysis
R&S
®
Scope Rider RTH
177User Manual 1326.1578.02 ─ 12
Figure 9-6: Decoded I2C signal, zoom into selected frame
9.1.2.3 Settings in the Protocol Menu
Access: "Protocol" menu
Track in Table
Sets the start of the selected frame (selected row) to the reference point.
Zoom Coupling
The setting is only available if "Track in Table" is active. It shows the comb of the
selected frame on full width of the screen. The resulting zoom time scale is shown
below the comb.
Basics of Protocol Analysis