EasyManua.ls Logo

Rohde & Schwarz Scope Rider RTH1004 - Probe<M>:Setup:attenuation:manual; Probe<M>:Setup:attenuation:unit

Rohde & Schwarz Scope Rider RTH1004
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
Scope Rider RTH
301User Manual 1326.1578.02 ─ 12
Suffix:
<m>
.
1|2 (RTH1002) , 1..4 (RTH1004)
Parameters:
<ProbeSettings> V1TO1 | V10To1 | V20To1 | V100to1 | V200to1 | V1000to1 |
C100V1A | C10V1A | C1V1A | C100MV1A | C10MV1A |
C1MV1A | T1MVC | T1MVF | PT100 | PT500 | PT1000 | USER
V1TO1 | V10To1 | V20To1 | V100To1 | V200To1 | V1000To1
Attenuation factors of voltage probes: 1:1, 10:1, 20:1, 100:1,
200:1, 1000:1.
C100V1A | C10V1A | C1V1A | C100MV1A | C10MV1A |
C1MV1A
Sensitivity of current probes: 100 V/A, 10 V/A, 1 V/A, 100 mV/A,
10 mV/A, 1 mV/A.
T1MVC | T1MVF | TPTC | TPTF
Temperature adapter type: 1 mV/°C, 1 mV/°F, PT100(°C),
PT100(°F)
USER
Set a user-defined attenuation factor if the predefined values do
not fit: Use PROBe<m>:SETup:ATTenuation:MANual to set
the value and PROBe<m>:SETup:ATTenuation:UNIT to set
the unit.
*RST:
V1TO1
PROBe<m>:SETup:ATTenuation:MANual <ProbeFactor>
Sets a user-defined attenuation factor if CHANnel<m>:PROBe is set to USER.
Suffix:
<m>
.
1|2 (RTH1002) , 1..4 (RTH1004)
Parameters:
<ProbeFactor> Range: 100E-6 to 10000
Increment: 100E-6
*RST: 1
PROBe<m>:SETup:ATTenuation:UNIT <ProbeUnit>
Sets a user-defined probe unit if CHANnel<m>:PROBe is set to USER.
Suffix:
<m>
.
1|2 (RTH1002) , 1..4 (RTH1004)
Parameters:
<ProbeUnit> V | A
*RST: V