Logic Analyzer (R&S RTH-B1 MSO)
R&S
®
Scope Rider RTH
252User Manual 1326.1578.02 ─ 12
Logic Channels
Enables or disables the logic channels.
Remote command:
LOGic:STATe on page 486
Visible
By default, all 8 logic channels are displayed. Disable the logic channels that you do
not need for analysis.
Couple Thresh.
Couples the threshold and hysteresis settings for the logic channels.
If enabled, all logic channels use the same threshold and hysteresis settings.
If disabled, 2 channel groups are available, which can use different threshold and hys-
teresis settings: D0 - D3, and D4 - D7.
Remote command:
LOGic:THCoupling on page 486
Threshold
Sets the threshold value for the selected channel group, or for all logic channels. For
each acquired sample, the instrument compares the input voltage with the threshold
value. If the input voltage is above the threshold, the signal state "1" is stored. Other-
wise, the signal state "0" is stored if the input voltage is below the threshold.