R&S SMC100A Command Description
1411.4060.32 6.57 E-1
Example:
LFO:FREQ:STAR
'sets the start frequency to 1 kHz.
LFO:FREQ:STOP
'
sets the stop frequency to 100 kHz.
LFO:SWE:SPAC LOG
'sets logarithmic sweep spacing.
LFO:SWE:STEP:LOG 10PCT
'sets the step width for logarithmic sweep spacing to 10% of the previous
frequency in each instance.
*RST value Resolution Options Correlation SCPI
1 PCT 0.01 PCT -
The value of :LFO:SWE:POIN is adjusted
automatically.
Device-specific
[SOURce:]LFOutput:VOLTage 0 V...4 V
The command sets the output voltage of the LF output.
Example:
LFO:VOLT 3 V
'sets the voltage of the LF output to 3 V.
*RST value Resolution Options SCPI
1 V 0.001 V - Device-specific
SOURce:MODulation Subsystem
This subsystem contains the command for switching on/off all modulations.
Command Parameters Default unit Remark
[SOURce:]MODulation[:ALL]:STATe ON | OFF
[SOURce:]MODulation[:ALL]:STATe ON | OFF
The command switches the modulations on and off. A subsequent command
:SOUR:MOD:ALL:STAT ON restores the status that was active before the last switch-off. MOD OFF
is displayed in the info line of the header next to the Level field.
Example:
MOD:STAT OFF
'switches off all active modulations
*RST value Resolution Options SCPI
ON - - Device-specific