User Manual Roth EnergyLogic Touchline/Wireless
Design and function
P100011294 E 25
LEDs Description
Cool:
Blue LED
On: C/O-input contact closed
(cooling mode active)
On: TB-C/O 24…230V input active
(as C/O-input configured)
On: Switch over heating/cooling by wireless room thermo-
stat (C/O-Output active)
Off: Wireless connection module in heating mode
% rH:
Red LED
On: Dew-point active only in cooling mode
Blinking: TB active in heating or cooling mode
NO: Yellow LED
On: Actuator NO (normally open)
Off: Actuator NC (normally closed)
CH 1…CH 12:
Green LEDs
On: Addressing completed and output active
Blinking: Ready for addressing
Blinking, followed by fast flashing: Addressing is deleted in
a few seconds.
Blinking fast: Channel in emergency mode
The number of channels (CH) depends on the version.
Table 5: LEDs wireless connection module