User Manual Roth EnergyLogic Touchline/Wireless
Reset values to factory setting (reset)
74 P100011294 E
8 Reset values to factory setting (reset)
8.1 Reset radio system to factory settings
With the following procedure the wireless room thermostat and the relevant
wireless connection module can be reset to factory settings.
► Reset all wireless room thermostats that are assigned to the wireless
connection module with parameter P-24, option "4" to factory settings.
See page 83, parameter description P-24, option "4".
► Press push buttons Master and System of the wireless connection module
simultaneously for 10 seconds.
► The LED Power of the wireless connection module goes off.
► The radio system is reset to factory settings as soon as the LED Power is
off.
8.2 Reset wireless connection module to factory setting
See parameter description P-24, page 83.
Reset values to factory
settings via wireless
connection module
► Press push buttons Master and System of the wireless connection module
simultaneously for 10 seconds.
► After a short time the LEDs Master and System blink 5 seconds.
► The LEDs Master and System blink fast another 5 seconds.
► At the wireless connection module "Master" the LEDs Master and System
go off.