Parameter descriptions
P100011294 E 81
9.3 Service menu
9.3.1 Enter service menu
P-SE
The service menu is protected with a service code. This service code can
be changed with parameter P-36. See parameter description P-36,
page 86.
The wireless room thermostat is in stand-by mode.
Press any button on the wireless room thermostat for 2 seconds.
The display changes into operation mode. The room temperature setpoint
blinks.
Press sensor button
5 seconds to enter the user menu. The display
shows P01.
Press sensor button
repeatedly until the display shows P-SE.
Press sensor button
. The display shows 0000.
Press sensor button
and to enter the service code. The factory set-
ting of the service code is 1234. Confirm each selected digit with sensor
button
.
If the service code is correct then the display shows P-20, otherwise the
display shows P-SE.
9.3.2 Select parameter group
Press sensor button
, to select parameter group P-20, P-30,
P-40, P-50 or P-60, e.g. P-30.
Press sensor button
, to confirm the selected parameter group P-30. The
display shows parameter P-31.
Press sensor button
, repeatedly to select a parameter of the parameter
group P-30. Press sensor button
e.g. twice. The display shows P-33.
Select one of the following steps:
Press sensor button
, to confirm selection.
Press sensor button
. The display shows P-34.
Press sensor button
or , to change the settings of the selected pa-
rameter.
Select one of the following steps:
Press sensor button
, to save the changed settings. The display
shows the next parameter Pxx.
Press sensor button
, to interrupt the procedure. Any changed set-
tings are not saved. The display shows the actual selected parameter.
Press sensor button
, to leave the parameter group. The display shows
the next parameter group, here e.g. P-40.
To leave the user menu press sensor button
. Any confirmed parameter
setting will be sent to the wireless connection module. The display shows
the operation mode. The room temperature setpoint blinks.