EasyManua.ls Logo

Roth EnergyLogic Touchline/wireless - Thermostat Without Display Issues

Roth EnergyLogic Touchline/wireless
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual Roth EnergyLogic Touchline/Wireless
Troubleshooting
P100011294 E 103
11.3 Wireless room thermostat without display
Interference/Display Possible cause Measure To be performed by
LED flashes continually Battery too weak Exchange batteries. Operator
Table 23: Troubleshooting: Wireless room thermostat without display
11.4 FAQs
FAQ Note
The setpoint temperature cannot be
set. The sensor buttons
and do
not react.
Check if the operating mode "Normal operation" has been selected. The
setpoint temperature cannot be set in the operating modes "Off (frost protec-
tion)" and "Reduced operation". See page 62, Kapitel 7.4.
The setpoint temperature cannot be
set to the desired value.
The setting range is limited. See page 78, parameter description P-03.
The wireless room thermostat shows
only SENS and does not react any
longer.
The sensor mode is active.
Press the wireless room thermostat sensor buttons and simultane-
ously for 10 seconds.
Time and date is requested for every
wireless room thermostat that is
addressed.
During addressing of wireless room thermostats to a new connection module
the input of time and date is prompted. This input can be skipped, however,
with every next wireless room thermostat that is added the time and date
prompt will pop-up until time and date are set. See page 64, chapter 7.5.
Sensor buttons of the wireless room
thermostat do not function properly.
Remove and replace the batteries. The wireless room thermostat executes a
calibration of the sensor buttons automatically. Do not touch the sensor but-
tons during calibration. Alternatively, one can wait for 4 minutes until the next
regular calibration has been executed. During this 4 minutes period the sen-
sor buttons my not be touched.
Is it possible to show other values at
the display than the room tempera-
ture?
Time or temperature can be selected.
See parameter description P-01, page 78.
Is it possible to deactivate the dis-
play?
Deactivate the display with parameter P-06, option "1".
See parameter description P-06, page 79.
How to correct the addressing of a
wireless room thermostat?
It is possible to directly address a wrongly addressed wireless room thermo-
stat to another channel. However, we recommend to delete the first connec-
tion before addressing to the new channel.
See page 55, chapter 7.1.5 and page 52, chapter 7.1.1.
How to find out which channels are
already assigned to a zone?
Press the button Zone of wireless connection module once, twice, or three
times. Each time the LEDs of the channels those are assigned to a zone light.
See page 59, chapter 7.2.
Is information lost during replace-
ment of batteries?
Information is not lost during replacement of the batteries. Date is stored at
the wireless connection module.
The pump does not switch off.
One or more radio channels are configured as "by-pass".
The wireless room thermostat is addressed to another channel.
The wireless room thermostat is in emergency mode. No information is
sent anymore. Press the relevant channel button on the wireless connec-
tion for 10 seconds. The corresponding LED goes off.

Table of Contents

Related product manuals