User Manual Roth EnergyLogic Touchline/Wireless
Parameter descriptions
P100011294 E 77
P-60
Control parameters
Parameter Description
P-61 Configure Eco or N/R input.
P-62 Configure C/O in-/TB-input.
P-63 Select control of pump "local" or "Master-wireless connection
module" (only with activated communication between wireless
connection modules).
P-64 Select NC or NO function of thermal actuators.
P-65 Select control algorithm.
P-66 Activate or deactivate function "optimized actuator control".
P-67 Select controlled first start-up of floor heating.
9.2 User menu
Enter user menu
The wireless room thermostat is in stand-by mode.
► Press any button on the wireless room thermostat for 2 seconds.
► The display changes into operation mode. The room temperature setpoint
blinks.
► Press sensor button
5 seconds to enter the user menu. The display
shows P01.
► Select one of the following options:
– Press sensor button
, to confirm the parameter selection.
– Press sensor button
, to select parameter P02.
► Press sensor button
or , to change the settings of the selected pa-
rameter.
► Select one of the following options:
– Press sensor button
to save the parameter change. The display
shows the next parameter Pxx.
– Press sensor button
, to interrupt the procedure. The parameter
change is not saved. The display shows the actual selected parameter.
– If no sensor button is pressed, the wireless room thermostat returns into
stand-by mode after 1 minute. The changed parameter is not saved.
► To leave the user menu press sensor button
. Any confirmed parameter
setting will be sent to the wireless connection module. The display shows
the operation mode.