Parameter descriptions
78 P100011294 E
Parameter Description
P-01 Set display in stand-by-mode.
Factory settings: room temperature
Operation
Press sensor button or , to select the displayed value change: room-, floor-,
outdoor temperature or time.
Floor and outdoor temperature are only available with certain versions and ac-
cessories.
Press sensor button
to confirm selection. The display shows P-02.
P-02
IR
Set setpoint for the minimal floor temperature.
Factory settings: 15 °C
Setting range: 15…30 °C
Increment: 0.5 °C
Operation
Press sensor button
or , to adjust the setpoint.
Press sensor button
to confirm the setpoint. The display shows P-03.
P-03 Set upper and lower limits for room temperature setpoint.
Factory settings:
Maximal setpoint temperature: 30 °C
Minimal setpoint temperature: 5 °C
Operation
Press sensor button . The display shows Hi30. (Hi: high).
Press sensor button or , to set the upper limit.
Press sensor button
. The display shows Lo05. (Lo: low).
Press sensor button
or , to set the lower limit.
Press sensor button to confirm the changed limits. The display shows P-04.
P-04 Change time programs.
Operation
See page 64, chapter 7.5.
P-05 Reset time programs to factory settings.
Operation
Press sensor button
. The display shows Pro1 for time program 1.
Press sensor button
or , to select between time programs Pro1, Pro2 or
Pro3.
Press sensor button
. The display shows no.
Press sensor button
or , to select between options no and yes.
Press sensor button to confirm the selection. The display shows P-06.