User Manual Roth EnergyLogic Touchline/Wireless
Parameter descriptions
80 P100011294 E
Parameter Description
P-10 Use this parameter to specify the function of the sensor button .
You may choose between the following functions:
● P-9H: Party function
● H-C: Direct switching heating/cooling
● Display of the floor temperature (for wireless room thermostats with IR only)
● Factory settings: Option "P-9H" (party function)
Push the sensor button to activate the target value "Normal operation" for the set
duration of 0 to 9 hours at most at once (party function).
The function is displayed by a prefixed "P". For example, a current room tempera-
ture of 24.3 °C is displayed as P24.3 °C.
● Options
– Option "P-9H" (party function):
Push the sensor button
to activate the target value "Normal operation" for
the set duration of 0 to 9 hours at most at once.
The function is displayed by a prefixed "P". For example, a current room
temperature of 24.3 °C is displayed as P24.3 °C.
– Option "H-C": Direct switching between heating/cooling
This option is not available if option "2" has been chosen for parameter
"P-51".
Push the sensor button
for 2 seconds to switch between the cooling and
heating mode. The display shows COOL or HEAT. Confirm switching to the
other mode with the sensor button
.
– Option "Display floor temperature"
This option is only available for wireless room thermostats with IR-sensor.
For this option, the display shows the floor temperature and the symbol
.
The display switches to sleeping mode after 10 seconds.
Operation
► Press the sensor button . The display shows P-9H.
► Press the sensor button
or to select an option.
► Press the sensor button . The display shows P-SE (access to the service
menu).
Table 15: User menu