User Manual Roth EnergyLogic Touchline/Wireless
Parameter descriptions
88 P100011294 E
Parameter Description
P-42
IR
Set floor temperature correction of wireless room thermostat with integrated IR-
sensor.
● Factory settings: Option "0"
● Options:
– 0, standard setting: suitable for wood floors
– 1, average compensation: suitable for plastic floorings
– 2, high compensation: suitable for ceramic floors
NOTE
● The specified settings apply at a room temperature of 22 °C.
● For dark floorings or if the room temperature is at approx. 25 °C, you need to
switch up the compensation factor one level for all floors except for ceramic
floors.
● No obstacles such as carpets, floorings or furniture must be placed in the meas-
uring range of the IR sensor.
● Glossy floorings, e.g. due to sun irradiation, may cause measuring errors at the
IR sensor.
Operation
► Press sensor button
. The display shows 0.
► Press sensor button
or , to select option 1 or 2.
► Select one of the following options:
– Press sensor button , to save the changed settings. The display shows the
next parameter P-43.
– Press sensor button , to interrupt the procedure. The display shows the se-
lected parameter.
P-43
IR
Set maximum floor temperature of wireless room thermostat with integrated IR-
sensor.
This parameter avoids that the floor temperature exceeds a maximum temperature
level.
ATTENTION
This function is not designed as a safety limiter. Therefore any liability for damages
to the floor construction or plant components is expressly excluded. If a safety tem-
perature limiter function is required then this has to be provided by an external
hardwired safety temperature limiter (STB).
● Factory settings: 35 °C
● Setting range: 26…35 °C
● Increment: 1 K
Operation
► Press sensor button . The display shows 35.
► Press sensor button
or , to change the value.
► Select one of the following options:
– Press sensor button , to save the changed settings. The display shows the
next parameter P-44.
– Press sensor button , to interrupt the procedure. The display shows the se-
lected parameter.