VOLTAGE SPECIFICATIONS UNDER NORMAL OPERATING CONDITIONS
Voltage measurements should be taken with power supplied by the switched on ignition key, whilst resistance
measurement should be performed with battery disconnected.
UNIT
actuator :
MEASUREMENT
resistance
current
voltage
2.3± 0.5 ohm
open circuit
0.15÷ 0.3A
1.5÷ 1.7A
1.9÷ 2.4A
0.3÷ 0.8V
3.6÷ 4V
4.5÷ 5.8V
CONDITION
between terminals
between terminals and
earth
card supplied
engine idling
full-load engine running
card supplied
engine idling
full-load engine running
UNIT
pick-up
MEASUREMENT
resistance
voltage
1000± 200 ohm
open circuit
3V alternated voltage
10V alternated voltage
CONDITION
between terminals
between terminals and
earth
during engine starting
engine idling
engine