SAMSUNG Programming
DCS-816 February, 1999
MMC 501 (Page 4 of 7)
CALLBACK NO ANS: This timer controls the time before the callback is
automatically cancelled when a callback detects Ring No
Answer.
CAMP ON RECALL: This timer controls the duration of time a camped–on call
will stay at a destination before recalling to the
transferring station.
CLIP DISPLAY TIME: The amount of time that the Calling Line ID information
remains on the keyset’ s display. While on a trunk
conversation, users are allowed to review received CLIP
by pressing SCROLL à CLIP soft key, but LCD will
automatically go back to trunk conversation status on
expiration of this timer.
CLIP MSG RECEIVE: The amount of time that the system will allow a valid
message from the C.O.
C.O. CLEAR TIME: The length of time a DTS key remains busy after
cleardown.
CO CONFIRM TIME: After this time, the outgoing call is disconnected or you
can hear the confirm tone.
C.O.–C.O. This timer monitors the duration of an unsupervised co-
DISCONNECT: nference; when it expires, both trunks are disconnected.
CONFER TONE INT: This timer controls the timing of intervals between the
tones heard by the parties in a conference.
CONFIRM TONE The tone heard when a feature is activated or deactiva-
TIME ted.
DIAL PASS TIME: This timer is the wait time for preventing the misdialling of
an outgoing call. After the last digit has been dialled, the
voice path is connected.
DISA DISCONNECT: This timer controls the maximum duration of a DISA call.
DISA LOCK OUT TM: This timer controls the duration of time a DISA call is not
allowed to be made after the DISA error counter has
expired (MMC 500).
DISA NOANS DISC.: This timer controls the duration of time a DISA call is
disconnected by force when called party is not answered.
DISA PASS CHECK: This timer defines the time period before the system
clears the incorrect passcode counter.
DISPLAY DELAY TM: This timer controls the duration a display is shown in the
LCD display. This timer also controls the duration of time
that error tone is heard.