SATEL INTEGRA 43
6. The DLOADX program will inform you about establishing connection by means of
a suitable message.
Initiating connection by SMS message
Required settings of the control panel:
• programmed control command, which, if sent in the SMS message, will initiate connection
with the DLOADX program.
1. Click on the button in the DLOADX program.
2. A drop-down menu will be displayed. Select “TCP/IP: DLOADX <- GSM/GPRS” in it.
3. A window will open. Enter the number of the TCP port which is to be used for
communication (identical to that programmed in the GSM module, unless communication
takes place via a network device redirecting to another port).
4. Having entered the number of TCP port, click the “Start” button. Activation of the server
for cellular data network connection will follow.
5. Send to the control panel the following SMS message:
xxxx= (“xxxx” – the control command to initiate establishment of communication with
DLOADX program) – the control panel is to connect to the computer address
programmed in the control panel,
xxxx=aaaa:p= (“xxxx” – the control command to initiate establishment of communication
with DLOADX program; “aaaa” – address of the computer with DLOADX program (IP
address or domain name); “p” – TCP port) – the control panel is to connect to the
computer whose address has been given in the SMS message and use for
communication the TCP port given in the SMS message.
6. The DLOADX program will inform you about establishing connection by means of
a suitable message.
Programming via the INT-GSM / INT-GSM LTE module
The INT-GSM / INT-GSM LTE module can be connected to the control panel (RS-232 ports
of control panel and INT-GSM / INT-GSM LTE module must be connected) or to the
ETHM-1 Plus module (RS-232 ports of control panel and ETHM-1 Plus module must be
connected).
If the INT-GSM / INT-GSM LTE module is connected to the ETHM-1 Plus module,
connection via the cellular data network is only used when connection via Ethernet
cannot be successfully established.
GPRS/LTE connection via the INT-GSM / INT-GSM LTE module connected to the control
panel can be established in one of the following methods:
1. Initiating connection from the keypad (by the control panel). The control panel can be
programmed only from specified location. This method is recommended when the alarm
system owner does not want the remote programming to be carried out without its
knowledge. The computer with DLOADX program must have a public IP address.
2. Initiating connection by SMS message. The computer with DLOADX program must have
a public IP address.
3. Establishing connection via the SATEL server. The control panel can be programmed
from any location. No public IP address is required for the computer with DLOADX
program.
Required settings of the control panel for all methods of establishing connection:
• EXTERNAL MODEM, MODEM ISDN/GSM/ETHM and ANSWERING – ETHM/GSM options
enabled.